Navigate the lattice: hubs for browsing, trends for pricing signals.
CONTACT INFORMATION|4|N743.23|WVE|N/A|ALANA.M.BOYER2.CIV@US.NAVY.MIL| ITEM UNIQUE IDENTIFICATION AND VALUATION (JAN 2023)|19|||||||||||||||||||| HIGHER-LEVEL CONTRACT QUALITY REQUIREMENT (DEC 2014)|1|See specification sections C and E| INSPECTION OF SUPPLIES--FIXED-PRICE (AUG 1996)|2||| INSPECTION AND ACCEPTANCE - SHORT VERSION|8||||||||| GENERAL INFORMATION-FOB-DESTINATION|1|B| WIDE AREA WORKFLOW PAYMENT INSTRUCTIONS (JAN 2023)|16|Stand-Alone Receiving Report - Certifications Combo - Receiving Report & Invoice - Material|N/A|TBD|N00104|TBD|N39040 - Certifications, S4306A - Material |N50286 |TBD|133.2|N/A|N/A|N39040 - Certifications |N/A| N/A|See DD FORM 1423|PORT_PTNH_WAWF_NOTIFICATION@NAVY.MIL ALANA.M.BOYER2.CIV@US.NAVY.MIL| NAVY USE OF ABILITYONE SUPPORT CONTRACTOR - RELEASE OF OFFEROR INFORMATION (3-18))|1|| WARRANTY OF SUPPLIES OF A NONCOMPLEX NATURE (JUNE 2003)|6|One year from date of delivery |One year from date of delivery ||||| WARRANTY OF DATA--BASIC (MAR 2014)|2||| BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM-BASIC (FEB 2024)|11|||||||||||| NOTICE OF TOTAL SMALL BUSINESS SET-ASIDE (OCT 2020)(DEVIATION 2020-O0008)|1|| ALTERNATE A, ANNUAL REPRESENTATIONS AND CERTIFICATIONS (OCT 2025)|13|||||||||||||| BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024))|5|||||| BUY AMERICAN-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024)|1|| ANNUAL REPRESENTATIONS AND CERTIFICATIONS (MAR 2025)(DEVIATION 2025-O0003 AND2025-O0004))|13|332919|750|||||||||||| NOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY PERPARDENESS, AND ENRGY PROGAM USE (APRIL 2008))|2||X| 1. DD1423 Data Item A001 (Inspection and Test Plan) may be waived if already on file at NAVSUP WSS Mechanicsburg. 2. Portsmouth NSY's DODAAC has changed from N00102 to N50286. Any reference to N00102 within this order should be updated to N50286. 3. The following proposed delivery schedule applies: Submission of Certification Data CDRLs will be on or before 20 days prior to scheduled delivery. PNSY review/acceptance of Certification CDRLs 6 working days after receipt of Certification DD 1423 CDRLs. Final delivery of material will be on or before 365 days after effective date of the resulting contract. 4. Any contract awarded as a result of this solicitation will be "DO" rated order; "DO" rated order certified for national defense use under the Defense Priorities and Allocations System (DPAS). 5. NAVSUP WSS Mechanicsburg will be considering past performance in the evaluation of offers in accordance with FAR 13.106(a)(2) and DFARS 252.213-7000. 6. If drawings are included in the solicitation, access needs to be requested on the individual solicitation page on Contracts Opportunities on the Government's beta.SAM website. After requesting access, send an email to the Primary POC listed on the solicitation. 7. This order is issued pursuant to Emergency Acquisition Flexibilities (EAF). \ 1. SCOPE 1.1 The material covered in this contract/purchase order will be used in a crucial shipboard system. The use of incorrect or defective material would create a high probability of failure resulting in serious personnel injury, loss of life, loss of vital shipboard systems, or loss of the ship itself. Therefore, the material has been designated as SPECIAL EMPHASIS material (Level I, Scope of Certification, or Quality Assured) and special control procedures are invoked to ensure receipt of correct material. 2. APPLICABLE DOCUMENTS 2.1 Order of Precedence - In the event of a conflict between the text of this contract/purchase order and the references and/or drawings cited herein, the text of this contract/purchase order must take precedence. Nothing in this contract/purchase order, however, must supersede applicable laws and regulations unless a specific exemption has been obtained. 2.2 Applicable Documents - The document(s) listed below form a part of this contract/purchase order including modifications or exclusions. 2.2.1 Specification Revisions - The specification revisions listed under "Documents References" below are the preferred revision. Older and/or newer r evisions are acceptable when listed within Contract Support Library Reference Number CSD155 in ECDS (Electric Contractor Data Submission) at: ht tps://register.nslc.navy.mil/. This is to allow Contractors to use certain acceptable older specification revisions to purge their existing stock of material certified to those older revisions or to use newer specification revisions when material is certified to newly released revisions,without requiring the submittal of waiver/deviation requests for each specification revision on every contract. Revisions of specifications reflecting editorial and/or re-approval (e.g. E2009, R2014, etc.) are considered inconsequential, but are acceptable when their revisions are listedwithin CSD155 or elsewhere within this contract. 2.2.2 Documents, drawings, and publications supplied are listed under "Drawing Number". These items should be retained until an award is made. 2.2.3 "Document References" listed below must be obtained by the Contractor. Ordering information is included as an attachment to this contract/purchase order. DRAWING DATA=H841-0311A02 |53711| A|ER |D|0001 | A|00026|0000000 DRAWING DATA=H841-0311A03 |53711| A|ER |D|0001 | A|49998|0063794 DRAWING DATA=H841-0311A03 |53711| A|ER |D|0002 | A|49998|0045143 DRAWING DATA=H841-0311A03 |53711| A|ER |D|0003 | A|49998|0019525 DRAWING DATA=H841-0311A03 |53711| A|ER |D|0004 | A|49998|0076636 DRAWING DATA=H841-0311A03 |53711| A|ER |D|0005 | A|49998|0081129 DRAWING DATA=H841-0311A03 |53711| A|ER |D|0006 | A|49998|0060643 DRAWING DATA=H841-0311A03 |53711| A|ER |D|0007 | A|49998|0059733 DRAWING DATA=H841-0311A03 |53711| A|ER |D|0008 | A|49998|0060515 DRAWING DATA=H841-0311A03 |53711| A|ER |D|0009 | A|49998|0058068 DRAWING DATA=H841-0311A03 |53711| A|ER |D|0010 | A|49998|0060261 DRAWING DATA=H841-0311A03 |53711| A|ER |D|0011 | A|49998|0059329 DRAWING DATA=H841-0311A03 |53711| A|ER |D|0012 | A|49998|0055878 DRAWING DATA=H841-0311A03 |53711| A|ER |D|0013 | A|49998|0059753 DRAWING DATA=H841-0311A03 |53711| A|ER |D|0014 | A|49998|0066702 DRAWING DATA=H841-0311A03 |53711| A|ER |D|0015 | A|49998|0065597 DRAWING DATA=H841-0311A03 |53711| A|ER |D|0016 | A|49998|0055280 DRAWING DATA=H841-0311A03 |53711| A|ER |D|0017 | A|49998|0256312 DRAWING DATA=H841-0311A03 |53711| A|ER |D|0018 | A|49998|0226401 DRAWING DATA=H841-0311A03 |53711| A|ER |D|0019 | A|49998|0151896 DRAWING DATA=H841-0311A03 |53711| A|ER |D|0020 | A|49998|0261479 DRAWING DATA=H841-0311A07 |53711| A|ER |D|0001 | A|49998|0049209 DRAWING DATA=H841-0311A07 |53711| A|ER |D|0002 | A|49998|0019529 DRAWING DATA=H841-0311A07 |53711| A|ER |D|0003 | A|49998|0064214 DRAWING DATA=H841-0311A07 |53711| A|ER |D|0004 | A|49998|0245768 DRAWING DATA=H841-0311A10 |53711| A|ER |D|0001 | A|49998|0052299 DRAWING DATA=H841-0311A10 |53711| A|ER |D|0002 | A|49998|0038687 DRAWING DATA=H841-0311A10 |53711| A|ER |D|0003 | A|49998|0071568 DRAWING DATA=H841-0311A10 |53711| A|ER |D|0004 | A|49998|0062986 DRAWING DATA=H841-0311A12 |53711| A|ER |D|0001 | A|49998|0062579 DRAWING DATA=H841-0311A12 |53711| A|ER |D|0002 | A|49998|0046869 DRAWING DATA=H841-0311A12 |53711| A|ER |D|0003 | A|49998|0070171 DRAWING DATA=H841-0311A12 |53711| A|ER |D|0004 | A|49998|0070640 DRAWING DATA=H841-0311A12 |53711| A|ER |D|0005 | A|49998|0071440 DRAWING DATA=H841-0311A12 |53711| A|ER |D|0006 | A|49998|0069962 DRAWING DATA=H841-0311A12 |53711| A|ER |D|0007 | A|49998|0069633 DRAWING DATA=H841-0311A12 |53711| A|ER |D|0008 | A|49998|0070395 DRAWING DATA=H841-0311A12 |53711| A|ER |D|0009 | A|49998|0070028 DRAWING DATA=H841-0311A12 |53711| A|ER |D|0010 | A|49998|0061605 DRAWING DATA=H841-0311A12 |53711| A|ER |D|0011 | A|49998|0059982 DRAWING DATA=H841-0311A12 |53711| A|ER |D|0012 | A|49998|0065829 DRAWING DATA=H841-0311A12 |53711| A|ER |D|0013 | A|49998|0079632 DRAWING DATA=H841-0311A12 |53711| A|ER |D|0014 | A|49998|0077596 DRAWING DATA=H841-0311A12 |53711| A|ER |D|0015 | A|49998|0054419 DRAWING DATA=H841-0311A16 |53711| A|ER |D|0001 | A|49998|0054082 DRAWING DATA=H841-0311A16 |53711| A|ER |D|0001.1 | A|49998|0049163 DRAWING DATA=H841-0311A16 |53711| A|ER |D|0001.2 | A|49998|0018325 DRAWING DATA=H841-0311A16 |53711| A|ER |D|0002 | A|49998|0073431 DRAWING DATA=H841-0311A16 |53711| A|ER |D|0003 | A|49998|0321693 DRAWING DATA=H841-0311A45 |53711| A|ER |D|0001 | A|49998|0472265 DRAWING DATA=7068535 |53711| A| |D|0000.A | A|49998|0073590 DRAWING DATA=7068535 |53711| A| |D|0001 | A|49998|0113855 DRAWING DATA=7068535 |53711| A| |D|0002 | A|49998|0073787 DRAWING DATA=7068535 |53711| A| |D|0003 | A|49998|0013516 DRAWING DATA=7068535 |53711| A| |D|0004 | A|49998|0017576 DRAWING DATA=7068535 |53711| A| |D|0005 | A|49998|0042496 DRAWING DATA=7068535 |53711| A| |D|0006.1 | A|49998|0088288 DRAWING DATA=7068535 |53711| A| |D|0006.2 | A|49998|0081582 DRAWING DATA=7068535 |53711| A| |D|0007.1 | A|49998|0036809 DRAWING DATA=7068535 |53711| A| |D|0007.10 | A|49998|0065677 DRAWING DATA=7068535 |53711| A| |D|0007.11 | A|49998|0080102 DRAWING DATA=7068535 |53711| A| |D|0007.12 | A|49998|0077264 DRAWING DATA=7068535 |53711| A| |D|0007.13 | A|49998|0054331 DRAWING DATA=7068535 |53711| A| |D|0007.2 | A|49998|0070235 DRAWING DATA=7068535 |53711| A| |D|0007.3 | A|49998|0070925 DRAWING DATA=7068535 |53711| A| |D|0007.4 | A|49998|0069720 DRAWING DATA=7068535 |53711| A| |D|0007.5 | A|49998|0069460 DRAWING DATA=7068535 |53711| A| |D|0007.6 | A|49998|0070275 DRAWING DATA=7068535 |53711| A| |D|0007.7 | A|49998|0069898 DRAWING DATA=7068535 |53711| A| |D|0007.8 | A|49998|0064791 DRAWING DATA=7068535 |53711| A| |D|0007.9 | A|49998|0059742 DRAWING DATA=7068535 |53711| A| |D|0008 | A|49998|0256964 DRAWING DATA=7068535 |53711| A| |D|0009 | A|49998|0226814 DRAWING DATA=7068535 |53711| A| |D|0010 | A|49998|0165069 DRAWING DATA=7068535 |53711| A| |D|0011 | A|49998|0149929 DRAWING DATA=7068535 |53711| A| |D|0012 | A|49998|0322268 DRAWING DATA=7068535 |53711| A| |D|0013 | A|49998|0106935 DRAWING DATA=7068535 |53711| A| |D|0014 | A|49998|0203470 DRAWING DATA=7068535 |53711| A| |D|0015 | A|49998|0165822 DRAWING DATA=7068535 |53711| A| |D|0016 | A|49998|0260634 DRAWING DATA=7068535 |53711| A| |D|0017 | A|49998|0157258 DRAWING DATA=7068535 |53711| A| |D|0018 | A|49998|0186764 DRAWING DATA=7068535 |53711| A| |D|0019 | A|49998|0097801 DRAWING DATA=7068535 |53711| A| |D|0020 | A|49998|0090271 DRAWING DATA=7068535 |53711| A| |D|0021 | A|49998|0164439 DOCUMENT REF DATA=ANSI/ASQ Z1.4 | | | |080101|A| | | DOCUMENT REF DATA=QQ-N-286 | | |G |001207|A| | | DOCUMENT REF DATA=MIL-STD-792 | | |F |060519|A| | | DOCUMENT REF DATA=MIL-STD-2132 | | |D |080310|F| |01| DOCUMENT REF DATA=ISO_9001 | | | |081115|A| | | DOCUMENT REF DATA=ISO10012 | | | |030415|A| | | DOCUMENT REF DATA=ISO/IEC 17025 | | | |050515|A| | | DOCUMENT REF DATA=MIL-I-45208 | | |A |810724|A| |01| DOCUMENT REF DATA=MIL-STD-45662 | | |A |880801|A| | | DOCUMENT REF DATA=ANSI/NCSL Z540.3 | | | |130326|A| | | DOCUMENT REF DATA=T9074-AS-GIB-010/271 | | |1 |140911|A| | | 3. REQUIREMENTS 3.1 ;Operating Rod, must be in accordance with Naval Sea Systems Command drawing 7068535 item number 62, and ER's ERH841-0311A2, ERH841-0311 A3, ERH841-0311A7, ERH841-311A10, ERH841-0311A12, ERH841-0311A16, and ERH841-0311A45, except as amplified or modified herein; 3.2 ;No weld repair allowed on QQ-N-286 Material.; 3.3 Material for Parts Requiring Certification - Quantitative chemical and mechanical analysis is required for the parts listed below unless specifically stated otherwise: Part - ;Operating Rod; Material - ;QQ-N-286, form 2, annealed & age hardened, finish A; 3.4 Testing Certification - Certifications are required for the following tests on the items listed below. Additional testing on other piece parts (if any) per applicable drawings and specifications is still required, but certifications are only required as listed below. Attribute - Annealing and Age Hardening Item - ;Operating Rod; Performance - QQ-N-286 Test - Ultrasonic Inspection on Starting Material Item - ;All Items requiring certification made from QQ-N-286 with a diameter or minimum distance between parallel surfaces of 4 inches or greater of the starting material, or when required by a drawing or specification invoked elsewhere in this contract; Performance - T9074-AS-GIB-010/271 or MIL-STD-2132, and QQ-N-286 Acceptance - QQ-N-286 3.5 Slow Strain Rate Tensile Test Laboratories - The Slow Strain Rate Tensile Test of QQ-N-286 must be performed by one of the following laboratories: Huntington Alloys, a Special Metals Company Attn: Bill Bolenr 3200 Riverside Drive Huntington, WV 257059 Phone: (304) 526-5889 FAX: (304) 526-5973 Metallurgical Consultants, Inc. Attn: W. M. Buehler 4820 Caroline PO Box 88046 Houston, TX 77288-0046 Phone: (713) 526-6351 FAX: (713) 526-2964 Naval Surface Warfare Center, Carderock Division Attn: Eric Focht Code 614 9500 Macarthur Blvd West Bethesda, MD 20817-5700 Phone: (301) 227-5032 FAX: (301) 227-5576 Teledyne Allvac Attn: Dr. W. D. Cao 2020 Ashcraft Ave. Monroe, NC 28110 Phone: (704) 289-4511 FAX: (704) 289-4269 Westmoreland Mechanical Testing and Research Inc. Attn: Andrew Wisniewski P.O. Box 388 Youngstown, PA 15696-0388 Mannesmann Rohrenwerke Mannesmann Forschungsinstitut (MFI) Attn: Dr. Weiss Postfach 251160 47251 Duisburg Germany Phone: 011-49-0203-9993194 FAX: 011-49-0203-9994415 ThyssenKrupp VDM USA, Inc. Attn: D. C. Agarwal 11210 Steeplecrest Drive, Suite 120 Houston, TX 77065-4939 Phone: (281) 955-6683 3.6 O-ring grooves and mating sealing surfaces must be inspected per the contractually invoked drawings or specifications. When the drawings or specifications do not provide specific defect criteria or state that no defects are allowed, the General Acceptance Criteria (GAC) standard must be used for inspecting O-ring grooves and mating sealing surfaces only. Repairs to sealing surfaces and O-ring grooves with unacceptable defects may be accomplished within the limits of the size and tolerances provided in the applicable drawing. Repairs thatwould exceed these limits require approval (including final dimensions). The data that is red lined (crossed out) is excluded from the GAC for this contract and is not to be used for acceptance or rejection criteria. The GAC document is identified as Contract Support Library Reference Number CSD008 at https://register.nslc.navy.mil/ 3.7 Certificate of Compliance - (SPECIAL EMPHASIS MATERIAL) The Contractor must prepare and submit a certificate of compliance certifying that the items/components furnished under this contract comply with the requirements of the procurement document, including any/all invoked specifications and drawings. 3.8 Configuration Control - The Contractor must maintain the total equipment baseline configuration. For items of proprietary design, Contractor drawings showing the latest assembly configuration must be provided to the Government in electronic (C4) format. Definitions are provided elsewhere in the Contract/Purchase Order. 3.8.1 Waivers/Deviations - All waivers and deviations, regardless of significance or classification require review and approval by the Contracting Officer. Waivers and Deviations must be designated as Critical, Major, or Minor. The Contractor must provide a copy of this request to the QAR. Requests must include the information listed below. a. A complete description of the contract requirement affected and the nature of the waiver/deviation (non-conformance), including a classification of Critical, Major, or Minor. b. Number of units (and serial/lot numbers) to be delivered in this configuration. c. Any impacts to logistics support elements (such as software, manuals, spares, tools, and similar) being utilized by Government personnel or impacts to the operational use of the product. d. Information about remedial action being taken to prevent reoccurrence of the non-conformance. 3.8.2 All requests for Waivers/Deviations on NAVSUP-WSS Contracts must be submitted to the NAVSUP WSS Contracting Specialist via eMail. 3.8.3 ECPs - The Government will maintain configuration control and change authority for all modifications or changes affecting form, fit, function, or interface parameters of the Equipment and its sub-assemblies. The Contractor must submit an Engineering Change Proposal (ECP) for any Class I or II changes that impact the Equipment covered by this contra…
Files size/type shown when available.
A practical, capture-style breakdown of fit, requirements, risks, and next steps.
It summarizes awarded-contract behavior for the opportunity’s NAICS and sector, including a recent pricing band (P10–P90), momentum, and composition. Use it as context, not a guarantee.
The signal updates as new awarded notices enter the system. Always validate the official award and solicitation details on SAM.gov.
P10 is the 10th percentile award size and P90 is the 90th percentile. Together they describe the typical spread of award values.
Awarded-market signal for NAICS 332919 (last 12 months), benchmarked to sector 33.