6515--NX EQ Electrosurgical Units, Argon-Enhanced Coagulation
Combined Synopsis Solicitation from VETERANS AFFAIRS, DEPARTMENT OF • VETERANS AFFAIRS, DEPARTMENT OF. Place of performance: Nationwide. Response deadline: Apr 16, 2026. Industry: NAICS 339113 • PSC 6515.
Market snapshot
Awarded-market signal for NAICS 339113 (last 12 months), benchmarked to sector 33.
Related hubs & trends
Navigate the lattice: hubs for browsing, trends for pricing signals.
Applicable Wage Determinations
SAM WDOL references matched to this opportunity's location and scope language.
Point of Contact
Agency & Office
More in NAICS 339113
Description
Combined Synopsis/Solicitation Notice Combined Synopsis/Solicitation Notice Page 3 of 14 Combined Synopsis/Solicitation Notice *= Required Field Combined Synopsis/Solicitation Notice Page 1 of 14 Solicitation Number: 36C10X26Q0059 Notice Type: Combined Synopsis/Solicitation Synopsis: COMBINED SYNOPSIS/SOLICITATION This is a combined synopsis/solicitation for commercial items prepared in accordance with (IAW) the format in Federal Acquisition Regulation (FAR) 12.202, Publicizing, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation will not be issued. Solicitation number 36C10X26Q0059 is issued for this combined synopsis/solicitation; this solicitation is being issued as a Request for Quote (RFQ). This combined synopsis/solicitation is issued under the agency's implementation of the Federal Acquisition Regulation (FAR) Overhaul, as adopted through agency class deviation. All applicable provisions, clauses, definitions, and procedures are those contained in the Overhaul text and the agency's implementation deviations. In the event of a conflict with the codified FAR, the adopted Overhaul text governs. The full text of provisions and clauses may be accessed electronically at https://www.acquisition.gov/far-overhaul/far-part-deviation-guide. Requirement Description: The Veterans Health Administration (VHA) Non-Expendable (NX) National Program has identified the Erbe® VIO 3, Electrosurgical Units, Argon-Enhanced Coagulation product line as a candidate for an Enterprise-wide (otherwise referred to as national ) single Requirements contract award. Electrosurgical Units (ESUs); Argon-Enhanced Coagulation (AEC) are advanced, energy based surgical systems used to perform precise tissue coagulation and devitalization across Veterans Affairs Medical Centers (VAMCs), particularly in operating rooms (OR), procedural suites, and endoscopy units. They deliver radiofrequency (RF) energy through specialized electrodes while directing a controlled flow of inert argon gas to create a conductive plasma at the tissue surface. This results in uniform, noncontact coagulation with minimal tissue penetration, improved visualization, and reduced bleeding. ESUs with AEC are designed to enhance surgical efficiency, improve hemostasis, and support consistent, replicable outcomes across a range of open, laparoscopic, and endoscopic procedures. These systems provide real-time, automated control of power delivery, argon flow, and activation mode, with integrated safety monitoring and configurable presets for procedure-specific use. They are optimized to increase clinical efficiency and reduce complications through precision energy delivery, reliable tissue effect profiles, and comprehensive safety interlocks. A single award Requirements contract will be awarded IAW all terms, conditions, provisions, specifications, and schedule of this solicitation herein. Quotes shall contain the terms for cost/price and technical capabilities of brand name equipment. The Government reserves the right to award without discussions. The associated North American Industrial Classification System (NAICS) code for this procurement is 339112 Surgical and Medical Instrument Manufacturing, Product Service Code: 6515 Medical and Surgical Instruments, Equipment, and Supplies and the associated size standard is 1,000 employees. This procurement action is issued as Full and Open. This acquisition is for a single award Requirements contract with firm-fixed priced (FFP) delivery orders IAW FAR Part 16.5 for Brand Name or Equal which requires the offeror indicate that each product being offered as an equal product to the Brand Name Olympus ESG-300 Electrosurgical System. Offerors shall provide a quote for all Contract Line-Item Numbers (CLINs) listed in ATTACHMENT A - PRICE COST SCHEDULE - NX EQ Electrosurgical Units, Argon-Enhanced Coagulation. The ordering period is for one 12-month base year with four 12-month option years. Delivery is Free on Board (FOB) destination. FFP Orders will be placed against this contract in writing and will provide the delivery locations, delivery dates and exact quantities.  The FAR provision at 52.212-1, Instructions to Offerors-Commercial Products And Commercial Services, applies to this acquisition including attached addenda to the provision (see ATTACHMENT D - SOLICITATION PROVISIONS - NX EQ Electrosurgical Units, Argon-Enhanced Coagulation). The FAR provision at 52.212-2, Evaluation-Commercial Products and Commercial Services, and the specific evaluation criteria as attached addenda also applies to this acquisition (see ATTACHMENT D - NX EQ Electrosurgical Units, Argon-Enhanced Coagulation). Clause at 52.212-4, Contract Terms and Conditions-Commercial Products and Commercial Services, applies to this acquisition and a statement regarding any addenda to the clause. (see ATTACHMENT C - CONTRACT CLAUSES NX EQ Electrosurgical Units, Argon-Enhanced Coagulation). All interested Offerors must be registered in the System for Award Management (SAM) prior to submitting a quote. You may access SAM at https://sam.gov/SAM/. Questions regarding this combined synopsis/solicitation are due via email by 11:59 PM EST on April 09, 2026, to Contract Specialist (CS) Daleta Coles, Daleta.Coles@va.gov and Contracting Officer (CO) Hosea Berkley, Hosea.Berkley@va.gov. No questions will be accepted after the due date. No calls will be accepted. Quotes are due via email by 11:59PM EST on April 15, 2026, to Contract Specialist (CS) Daleta Coles, Daleta.Coles@va.gov and Contracting Officer (CO) Hosea Berkley, Hosea.Berkley@va.gov PRODUCT DESCRIPTION 1. SCOPE OF WORK The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified Electrosurgical Units (ESUs); Argon-Enhanced Coagulation product line as a candidate for a VA-wide (otherwise referred to as national ) single Requirements contract award. Electrosurgical Units (ESUs); Argon-Enhanced Coagulation (AEC) are advanced, energy based surgical systems used to perform precise tissue coagulation and devitalization across Veterans Affairs Medical Centers (VAMCs), particularly in operating rooms (OR), procedural suites, and endoscopy units. They deliver radiofrequency (RF) energy through specialized electrodes while directing a controlled flow of inert argon gas to create a conductive plasma at the tissue surface. This results in uniform, noncontact coagulation with minimal tissue penetration, improved visualization, and reduced bleeding. ESUs with AEC are designed to enhance surgical efficiency, improve hemostasis, and support consistent, replicable outcomes across a range of open, laparoscopic, and endoscopic procedures. These systems provide real-time, automated control of power delivery, argon flow, and activation mode, with integrated safety monitoring and configurable presets for procedure-specific use. They are optimized to increase clinical efficiency and reduce complications through precision energy delivery, reliable tissue effect profiles, and comprehensive safety interlocks. Offerors must demonstrate the ability to meet all requirements for the solicitation. The objective is to provide an Electrosurgical Units (ESUs); Argon Enhanced Coagulation system to be used by clinicians throughout the VA medical centers and facilities. The period of performance is for a 12-month base period and four 12-month option periods. 2. REQUIREMENT This requirement will be solicited and awarded as a Brand Name or Equal which requires the quoter indicate that each product being offered as an equal product to the Erbe® VIO 3 Electrosurgical Units (ESUs); Argon-Enhanced Coagulation system. For each equal product, the offeror must include a description reflecting the salient characteristics (SC) and level of quality that will satisfy the salient physical, functional, or performance characteristics of the equal product(s) specified in the solicitation. The quoter must also clearly identify the item by brand name (if any) and make/model number. Finally, the quoter must include descriptive literature, such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available to the Contracting Officer and clearly describe any modifications it plans to make to a product to conform to the solicitation requirements. The following line-items comprise the Erbe® VIO 3 Electrosurgical Units (ESUs); Argon-Enhanced Coagulation system product line: Contract Line-Item Brand Part Number Description 0001 ERBE USA Inc. VIO® 3 0001A ERBE USA Inc. 10160-000 VIO® Electrosurgical unit 0001B ERBE USA Inc. 20189-353 Two-pedal foot switch, VIO® 3 ReMode®, bracket, middle piece 0001C ERBE USA Inc. 20188-350 One-pedal foot switch, VIO® 3 ReMode® 0001D ERBE USA Inc. 20180-000 VIO® CART System carrier for VIO® 0001E ERBE USA Inc. 20180-010 Wire basket, 339 x 205 x 155 / 100 mm 0002 ERBE USA Inc. Attachment Sets 0002A ERBE USA Inc. 20180-140 Fastening set for VIO® 3 on VIO® Cart 0002B ERBE USA Inc. 20180-143 Fastening set VIO® 3 for APC® 3 on boom mount 0002C ERBE USA Inc. 20180-144 Fastening set VIO® 3 for APC® 3 on ERBEJET® 2 0003 ERBE USA Inc. Instrument cables from Erbe 0003A ERBE USA Inc. 20192-133 Monopolar cable MO 3Pin; MIS OD 4mm; L 4.5m 0003B ERBE USA Inc. 20192-134 Monopolar cable MO 3Pin; OD 4.5mm pin; L 4.5m 0003C ERBE USA Inc. 20192-135 Monopolar cable MO 3Pin; OD 3mm socket; L 4.5m 0003D ERBE USA Inc. 20196-064 Bipolar cable BI 2Pin28; ang.; forceps; L 4.5m 0003E ERBE USA Inc. 20196-067 Bipolar cable BI 2Pin28; grasp. forceps; L 4.5m 0003F ERBE USA Inc. 20196-127 Bipolar cable BI 2Pin28; forceps 2Pin; L 4m 0003G ERBE USA Inc. 21196-115 Bipolar Connecting Cable; MF-U Olympus Resectoscope; L 4.5m 0003H ERBE USA Inc. 21196-118 Bipolar Connecting Cable; MF-U Storz Resectoscope; L 4.5m 0003I ERBE USA Inc. 21196-119 Bipolar Connecting Cable; MF-U Wolf Resectoscope; L 4.5m 0004 ERBE USA Inc. VIO® 300 D 0004A ERBE USA Inc. 10140-100 VIO® 300 D Electrosurgical Unit 120V/60HZ UL , Software Version 2.X Constant Voltage 0004B ERBE USA Inc. 20189-305 VIO® two pedal footswitch w/ReMode® w/Bracket (Remode Feature Allows Changing between Preset Programs) 0004C ERBE USA Inc. 20180 131 Connection Adapter, Cryo Probe to Erbokryo CA 0004D ERBE USA Inc. 20183-053 Adapter for BICAP or Gold Probe 0004E ERBE USA Inc. 20193-084 NESSY® Omega monitoring pad with cable (50 per case) 0004F ERBE USA Inc. 20180-000 VIO® Cart with footswitch holder, cable wrap and 1 tank fixation kit 0004G ERBE USA Inc. 20180-010 VIO® Cart wire basket 0004H ERBE USA Inc. 20180-131 VIO®/APC® 2 to VIO® Cart fastening set (with grounding cable) The VA is seeking offerors who can provide Erbe® VIO 3 Electrosurgical Units (ESUs); Argon-Enhanced Coagulation system or equal as listed above which meet all the following salient characteristics: Vendors may quote any product solution or configuration so long as they meet the salient characteristics. Offerors may quote an alternative CLIN structure IAW FAR 4.202-2 and 4.202-3. Products quoted in the technical volume must appear on and correspond with the Offeror s pricing volume (ATTACHMENT A - PRICE COST SCHEDULE - NX EQ Electrosurgical Units, Argon-Enhanced Coagulation). Offerors may quote any additional ancillary products which they deem to be essential to the functionality of the quoted solution; these ancillary items must be quantified in the Offeror s pricing volume with an estimated quantity of zero (0). Only new equipment is acceptable; no remanufactured or "gray market" items. No product in development shall be considered. All items must be covered by the manufacturer's warranty. Distributors must be authorized-distributors/resellers as certified by the Original Equipment Manufacturer (OEM) (i.e., OEM letter dated within 12 months of the solicitation close date and duly signed by OEM s authorized representative) to be eligible for award. The OEM letter must be valid for the life of the contract. CLIN s 0001 apply to SC s 0001-0004 SC # SALIENT CHARACTERISTICS METHOD OF EVALUATION SC Literature Map (Brand Name/Page #) SC 1 Must be cleared by the U.S. Food and Drug Administration (FDA) as an electrosurgical generator with compatible argon-enhanced coagulation capability for cutting and coagulation of tissue in general, laparoscopic, and endoscopic surgery, including hemostasis and devitalization of soft tissues. Literature Review SC 2 Must provide a centralized color touchscreen user interface that allows the operator to select, monitor, and adjust at minimum: Electrosurgical mode (e.g., monopolar cut, monopolar coagulation, bipolar, argon coagulation); Output power settings (watts); Application-relevant parameters (e.g., argon gas flow and effect settings for argon-enhanced coagulation); and Treatment or activation time (timer or activation counters). Literature Review SC 3 Must be compatible with a range of monopolar and bipolar instruments, as well as compatible argon probes/catheters and applicators, in various working lengths suitable for open and endoscopic procedures. Literature Review SC4 Must consist of modular argon plasma capability with adjustable gas flow rates (0.1 to 6 L/min) and multiple APC waveforms (precise, pulsed, forced) for non-contact surface coagulation, enabling effective hemostasis and tissue ablation in gastrointestinal, respiratory, and other anatomical applications. Literature Review SC 5 Must have advanced neutral electrode monitoring (such as NESSY technology) that dynamically tracks patient impedance levels and return electrode contact/orientation, along with proprietary spark recognition and control algorithms to minimize carbonization, tissue adhesion, and unintended thermal injury. Literature Review SC 6 Must consist of compact design with multiple socket configurations (monopolar, bipolar, universal connections) accommodating international and manufacturer-specific instrument standards, wireless and wired footswitch options, and compatibility with smoke evacuation and insufflation systems for streamlined OR workflow. Literature Review SC7 Must include a minimum one year manufacturer warranty covering parts and labor, with availability of installation, user training, and ongoing service support programs. Literature Review Evaluation Sub-factors 1. Design: Design features and function will be evaluated based on, but not limited to, the following: Centralized touchscreen user interface: Large, color touchscreen with logical application-oriented men for quick selection and confirmation of modes to include APC settings. Multi-instrument connectivity and APC integration to include argon probes and APC hand pieces. Procedure and instrument-based presents: Recognizes instrument and procedure-specific programs that automatically load parameters and standardizes set-up. 2. Performance: Performance capabilities, features and functions of the device offered will be evaluated for technical performance, reliability, and clinical effectiveness. These elements include, but are not limited to: High dynamic power delivery: Power supply is able to maintain stable output under variable loads and APC modes. Rapid response measurement rate: High measurement of frequency of target tissue effects across different tissue types and cutting speeds supporting argon-assisted coagulation lines. Multi-modality support: Concurrent support for monopolar, bipolar, and hybrid/argon-assisted applications across platforms without swapping generators during an on-going procedure. 3. Safety: All features and functions of the equipment shall be evaluated for the ability to be safely installed, secured, and protected against harm; physical or any form. These elements include, but are not limited to: Regulatory compliance and clearances: FDA 510(K) clearance status. Systems and operational features safety related to electrical and argon-gas. Warning and alarms capability 4. Quality/Construction/Training: Elements will include, but are not limited to: Robust construction and medical-grade standards. Power consumption, backup power, and energy efficiency. Terms and conditions of installation, training, and service agreement programs. Expected life cycle to include sanitation, infection control, and maintenance. 3. PRODUCT REFRESH  Product refresh is when a current CLIN is no longer being manufactured due to obsolescence and the product item is being replaced with a newer, and more often, a superior version of the same item. The current CLIN product will be revised to reflect the refreshed product information, manufacturer s part number, IDIQ price (inclusive of Service Level Agreement (SLA) fee), etc. The Government reserves the right to not accept the products quoted under product refresh. The contractor will be notified in writing if a product refresh is not accepted. All products quoted shall be provided with the warranty that is agreed upon for this contract. The contractor agrees to ensure that all upgraded improved/replaced products meet American with Disabilities Act (ADA) and Health Information Portability and Accountability Act (HIPAA) Federal requirements. The contractor shall provide the Contracting Officer s Representative (COR) and Contracting Officer the following information for product refresh: (1) A list of specific awarded item(s) being refreshed in the Price/Cost Schedule (to include commercial pricing, discount offered, and IDIQ price (inclusive of SLA fee)); (2) Product literature for the item(s) refreshed. (3) A detailed description of the differences or benefits of refreshed as compared to the item(s) being discontinued or added. (4) Proper identification of any product requirements and/or procedures related to those product(s) quoted to be refreshed or upgraded. (5) FDA approval, if applicable (6) Provide historical sales to VA by item(s), if applicable (7) Copy of Commercial Warranty. The request shall be submitted to the COR for review and recommendation of approval to be submitted to the Contracting Officer. The Contracting Officer shall prepare a bilateral modification for execution. 4. PRODUCT REMOVAL OR RECALL For any product awarded under this contract removed or recalled by the manufacturer due to defects in the product or potential dangers to patients, or if any required removal or recall is suggested or mandated by a regulatory or official agency, the manufacturer agrees to take following steps immediately: Notify the Contracting Officer at the Strategic Acquisition Center in writing, by the most expeditious manner possible. Provide copies of the notification to the Contracting Officer, COR, and Manager at Product Recall Office, all Agencies and VA Facilities who purchased the product, which include, but not limited to the following: (1) Complete item description and/or identification, order numbers from customers and the contract number assigned as a result of an issuance on the solicitation; (2) Reasons for modifications, removal or recall; and (3) Necessary instructions for return for credit, replacement or corrective action. A copy of the notification will be provided to: Manager, Product Recall Office National Center for Patient Safety Veterans Health Administration 24 Frank Lloyd Wright Drive, Lobby M Ann Arbor, MI 48106 5. DELIVERY The Period of Performance will be from date of award for a base of 12-months with four 12-month option periods. Offerors will be required to deliver Electrosurgical Units, Argon-Enhanced Coagulation systems. to VHA facilities located in the Continental United States (CONUS) and Outside of the Continental United States (OCONUS). Delivery requirements shall be specified under each individual order. 6. DATA RIGHTS Commercial license agreements may be made a part of this Contract…
Files
Files size/type shown when available.
BidPulsar Analysis
A practical, capture-style breakdown of fit, requirements, risks, and next steps.
FAQ
How do I use the Market Snapshot?
It summarizes awarded-contract behavior for the opportunity’s NAICS and sector, including a recent pricing band (P10–P90), momentum, and composition. Use it as context, not a guarantee.
Is the data live?
The signal updates as new awarded notices enter the system. Always validate the official award and solicitation details on SAM.gov.
What do P10 and P90 mean?
P10 is the 10th percentile award size and P90 is the 90th percentile. Together they describe the typical spread of award values.