Skip to content
DHS - Human Services

TDF- Fire System FY27-FY28 SP

Solicitation: Not available
Notice ID: 27-444DHS-MENTH-B-51381

Federal opportunity from MENTHLTH444 - Mental Health • DHS - Human Services. Place of performance: IL. Response deadline: Mar 31, 2026.

Market snapshot

Baseline awarded-market signal across all contracting (sample of 400 recent awards; refreshed periodically).

12-month awarded value
$533,953,549
Sector total $533,953,549 • Share 100.0%
Live
Median
$139,000
P10–P90
$30,125$967,312
Volatility
Volatile200%
Market composition
NAICS share of sector
A simple concentration signal, not a forecast.
100.0%
share
Momentum (last 3 vs prior 3 buckets)
+100%($533,953,549)
Deal sizing
$139,000 median
Use as a pricing centerline.
Live signal is computed from awarded notices already observed in the system.
Signals shown are descriptive of observed awards; not a forecast.

Related hubs & trends

Navigate the lattice: hubs for browsing, trends for pricing signals.

We write these bids →
Open on official portal →
Map for IL
Live POP
Place of performance
DHS Contact 17019 County Farm Road Rushville, IL 62681 US Email: noreply@illinois.gov Phone: (217) 322-3204
State: IL
Contracting office
Not listed

Applicable Wage Determinations

SAM WDOL references matched to this opportunity's location and scope language.

WD Directory →
Best fit for this contractDavis-Bacon
IL20260002 (Rev 3)
Match signal: state matchOpen WD
Published Jan 23, 2026Illinois • Alexander, Champaign, Christian +38
Rate
tes Fringes Asbestos Workers/Insulator Includes the application, installation, and cleanup of all insulating materials, protective coverings, coatings, and finishings to all types of mechanical systems
Base $43.48Fringe $27.24
Rate
ASBESTOS WORKER/INSULATOR Includes the application of all insulating materials, protective coverings, coatings, and finishes to all types of mechanical systems
Base $55.02Fringe $35.75
+182 more occupation rates available in the full WD.
View more for this contract
3 more WD matches and 182 more rate previews.
Davis-BaconBest fitstate match
IL20260002 (Rev 3)
Open WD
Published Jan 23, 2026Illinois • Alexander, Champaign, Christian +38
Rate
tes Fringes Asbestos Workers/Insulator Includes the application, installation, and cleanup of all insulating materials, protective coverings, coatings, and finishings to all types of mechanical systems
Base $43.48Fringe $27.24
Rate
ASBESTOS WORKER/INSULATOR Includes the application of all insulating materials, protective coverings, coatings, and finishes to all types of mechanical systems
Base $55.02Fringe $35.75
Rate
Fire Stop Technician
Base $44.02Fringe $32.76
+181 more occupation rates in this WD
Davis-Baconstate match
IL20260007 (Rev 1)
Open WD
Published Jan 16, 2026Illinois • Madison, St Clair
Rate
ASBESTOS WORKER/HEAT & FROST INSULATOR
Base $43.48Fringe $27.24
Rate
BOILERMAKER
Base $45.50Fringe $35.30
Rate
Bricklayer, Caulker, Cleaner, Pointer & Stonemason (including Marble Mason, Tile Layer)
Base $33.13Fringe $22.05
+62 more occupation rates in this WD
Davis-Baconstate match
IL20260037 (Rev 1)
Open WD
Published Jan 16, 2026Illinois • Union
Rate
BRICKLAYER
Base $30.79Fringe $21.69
Rate
Carpenter/Drywall Hanger (including Batt Insulator)
Base $31.30Fringe $18.90
Rate
ELECTRICIAN Work not to exceed 8-plex family housing units
Base $32.58Fringe $12.11
+7 more occupation rates in this WD
Davis-Baconstate match
IL20260024 (Rev 2)
Open WD
Published Jan 16, 2026Illinois • Williamson
Rate
BRICKLAYER
Base $30.79Fringe $21.69
Rate
Carpenter/Drywall Hanger (including Batt Insulator)
Base $31.30Fringe $18.90
Rate
ELECTRICIAN Work not to exceed 8-plex family housing units
Base $32.58Fringe $12.11
+7 more occupation rates in this WD

Point of Contact

Not available

Agency & Office

Department
DHS - Human Services
Agency
MENTHLTH444 - Mental Health
Subagency
MENTHLTH444 - Mental Health
Office
AA011 - Treatment & Detention Facility - Rushville
Contracting Office Address
Not available

Description

TDF- Fire System FY27-FY28 SP The Department of Human Services is seeking bids for a two-year contract for the fire system repair and maintenance at the facility. It is essential to the facility that this system continues to operate correctly to protect the safety of staff and residents. Item # 1: Fire System Repair and Maintenance FY27. This item is for informational purposes only and is not meant to have pricing added, do not submit an amount for this line item. Preventative maintenance, repair and maintenance services, testing and inspections and emergency services when required. Items to be included in testing and inspection include: 1 annunciator panel, 332 smoke detectors, 10 Simplex 4100ES, 1 Simplex 4120 multiplex alarm panel, 51 duct detectors, 163 heat detectors, 39 manual pull stations, 114 audio/visual units, 188 visual units, 8 FMO 200 areas, 45 risers, 45 flow switches, 11 fire hydrants, 80-90 duct dampers, 30 tamper switches, 80 fire extinguishers, 10 supervised IM, 14 relay IM, 1 SSD sensor base with CO module, 1 smoke control system, 1 kitchen hood unit, 5 horn strobes and 1 strobe. Vendor will conduct quarterly visual and functional inspection testing and maintenance of fire alarm, detection, suppression, and smoke evacuation systems. All testing and inspections of the fire alarm system must be conducted in accordance with the most current version of the National Fire Protection Association. Fire System Repair and Maintenance FY27. This item is for informational purposes only and is not meant to have pricing added, do not submit an amount for this line item. Preventative maintenance, repair and maintenance services, testing and inspections and emergency services when required. Items to be included in testing and inspection include: 1 annunciator panel, 332 smoke detectors, 10 Simplex 4100ES, 1 Simplex 4120 multiplex alarm panel, 51 duct detectors, 163 heat detectors, 39 manual pull stations, 114 audio/visual units, 188 visual units, 8 FMO 200 areas, 45 risers, 45 flow switches, 11 fire hydrants, 80-90 duct dampers, 30 tamper switches, 80 fire extinguishers, 10 supervised IM, 14 relay IM, 1 SSD sensor base with CO module, 1 smoke control system, 1 kitchen hood unit, 5 horn strobes and 1 strobe. Vendor will conduct quarterly visual and functional inspection testing and maintenance of fire alarm, detection, suppression, and smoke evacuation systems. All testing and inspections of the fire alarm system must be conducted in accordance with the most current version of the National Fire Protection Association. Item # 2: Fire System Repair and Maintenance FY28. This item is for informational purposes only and is not meant to have pricing added, do not submit an amount for this line item. Preventative maintenance, repair and maintenance services, testing and inspections and emergency services when required. Items to be included in testing and inspection include: 1 annunciator panel, 332 smoke detectors, 10 Simplex 4100ES, 1 Simplex 4120 multiplex alarm panel, 51 duct detectors, 163 heat detectors, 39 manual pull stations, 114 audio/visual units, 188 visual units, 8 FMO 200 areas, 45 risers, 45 flow switches, 11 fire hydrants, 80-90 duct dampers, 30 tamper switches, 80 fire extinguishers, 10 supervised IM, 14 relay IM, 1 SSD sensor base with CO module, 1 smoke control system, 1 kitchen hood unit, 5 horn strobes and 1 strobe. Vendor will conduct quarterly visual and functional inspection testing and maintenance of fire alarm, detection, suppression, and smoke evacuation systems. All testing and inspections of the fire alarm system must be conducted in accordance with the most current version of the National Fire Protection Association. Fire System Repair and Maintenance FY28. This item is for informational purposes only and is not meant to have pricing added, do not submit an amount for this line item. Preventative maintenance, repair and maintenance services, testing and inspections and emergency services when required. Items to be included in testing and inspection include: 1 annunciator panel, 332 smoke detectors, 10 Simplex 4100ES, 1 Simplex 4120 multiplex alarm panel, 51 duct detectors, 163 heat detectors, 39 manual pull stations, 114 audio/visual units, 188 visual units, 8 FMO 200 areas, 45 risers, 45 flow switches, 11 fire hydrants, 80-90 duct dampers, 30 tamper switches, 80 fire extinguishers, 10 supervised IM, 14 relay IM, 1 SSD sensor base with CO module, 1 smoke control system, 1 kitchen hood unit, 5 horn strobes and 1 strobe. Vendor will conduct quarterly visual and functional inspection testing and maintenance of fire alarm, detection, suppression, and smoke evacuation systems. All testing and inspections of the fire alarm system must be conducted in accordance with the most current version of the National Fire Protection Association. Item # 3: ( 936 - 09 ) Fire System Repair and Maintenance FY27 (July 1, 2026 - June, 30 2027). Pricing based on cost per hour/unit of annual estimated hours/services for repair and maintenance services during normal business hours of Monday - Friday 7:00am - 3:00pm (estimated at 24). All testing and inspections of the fire alarm system must be conducted in accordance with the most current version of the National Fire Protection Association. Fire System Repair and Maintenance FY27 (July 1, 2026 - June, 30 2027). Pricing based on cost per hour/unit of annual estimated hours/services for repair and maintenance services during normal business hours of Monday - Friday 7:00am - 3:00pm (estimated at 24). All testing and inspections of the fire alarm system must be conducted in accordance with the most current version of the National Fire Protection Association. Item # 4: ( 936 - 09 ) Fire System Repair and Maintenance FY27 (July 1, 2026 - June 30, 2027). Pricing based on cost per hour/unit of annual estimated hours/services for repair and maintenance services outside of normal business hours (After 3:00pm Monday - Friday and on Saturdays) (estimated at 8). All testing and inspections of the fire alarm system must be conducted in accordance with the most current version of the National Fire Protection Association. Fire System Repair and Maintenance FY27 (July 1, 2026 - June 30, 2027). Pricing based on cost per hour/unit of annual estimated hours/services for repair and maintenance services outside of normal business hours (After 3:00pm Monday - Friday and on Saturdays) (estimated at 8). All testing and inspections of the fire alarm system must be conducted in accordance with the most current version of the National Fire Protection Association. Item # 5: ( 936 - 09 ) Fire System Repair and Maintenance FY27 (July 1, 2026 - June, 30 2027). Pricing based on cost per hour/unit of annual estimated hours/services for repair and maintenance services Sunday and Holidays (estimated at 8). All testing and inspections of the fire alarm system must be conducted in accordance with the most current version of the National Fire Protection Association. Fire System Repair and Maintenance FY27 (July 1, 2026 - June, 30 2027). Pricing based on cost per hour/unit of annual estimated hours/services for repair and maintenance services Sunday and Holidays (estimated at 8). All testing and inspections of the fire alarm system must be conducted in accordance with the most current version of the National Fire Protection Association.

Files

Files size/type shown when available.

BidPulsar Analysis

A practical, capture-style breakdown of fit, requirements, risks, and next steps.

Analysis is being generated for this notice. Check back shortly.

FAQ

How do I use the Market Snapshot?

It summarizes awarded-contract behavior for the opportunity’s NAICS and sector, including a recent pricing band (P10–P90), momentum, and composition. Use it as context, not a guarantee.

Is the data live?

The signal updates as new awarded notices enter the system. Always validate the official award and solicitation details on SAM.gov.

What do P10 and P90 mean?

P10 is the 10th percentile award size and P90 is the 90th percentile. Together they describe the typical spread of award values.