Skip to content
Department of Veterans Affairs

6680--Loch Raven Boiler Fuel Reserve Tank

Solicitation: 36C24526Q0377
Notice ID: ba0e4bfdb51e4fd69ff890acd65c8239
TypeCombined Synopsis SolicitationNAICS 333914PSC6680Set-AsideSBADepartmentDepartment of Veterans AffairsStateMDPostedApr 01, 2026, 12:00 AM UTCDueApr 06, 2026, 04:00 PM UTCExpired

Combined Synopsis Solicitation from VETERANS AFFAIRS, DEPARTMENT OF • VETERANS AFFAIRS, DEPARTMENT OF. Place of performance: MD. Response deadline: Apr 06, 2026. Industry: NAICS 333914 • PSC 6680.

Market snapshot

Awarded-market signal for NAICS 333914 (last 12 months), benchmarked to sector 33.

12-month awarded value
$15,963,624
Sector total $52,182,378,817 • Share 0.0%
Live
Median
$34,320
P10–P90
$31,090$80,760
Volatility
Volatile145%
Market composition
NAICS share of sector
A simple concentration signal, not a forecast.
0.0%
share
Momentum (last 3 vs prior 3 buckets)
-40%(-$3,943,248)
Deal sizing
$34,320 median
Use as a pricing centerline.
Live signal is computed from awarded notices already observed in the system.
Signals shown are descriptive of observed awards; not a forecast.

Related hubs & trends

Navigate the lattice: hubs for browsing, trends for pricing signals.

We write these bids →
Open on SAM.gov →
Map for MD
Live POP
Place of performance
Loch Raven MD VA Medical Center 3901 Loch Raven Blvd, Baltimore, MD. 21218 • United States
State: MD
Contracting office
Linthicum, MD • 21090 USA

Applicable Wage Determinations

SAM WDOL references matched to this opportunity's location and scope language.

WD Directory →
Best fit for this contractDavis-Bacon
MD20260115 (Rev 0)
Match signal: state matchOpen WD
Published Jan 02, 2026Maryland • Frederick
Rate
BALANCING TECHNICIAN
Base $47.92Fringe $24.44
Rate
BRICKLAYER
Base $37.50Fringe $14.78
+78 more occupation rates available in the full WD.
View more for this contract
3 more WD matches and 78 more rate previews.
Davis-BaconBest fitstate match
MD20260115 (Rev 0)
Open WD
Published Jan 02, 2026Maryland • Frederick
Rate
BALANCING TECHNICIAN
Base $47.92Fringe $24.44
Rate
BRICKLAYER
Base $37.50Fringe $14.78
Rate
CARPENTER
Base $34.41Fringe $14.49
+77 more occupation rates in this WD
Davis-Baconstate match
MD20260122 (Rev 0)
Open WD
Published Jan 02, 2026Maryland • Queen Anne's
Rate
BALANCING TECHNICIAN
Base $32.00Fringe $8.29
Rate
BRICKLAYER
Base $37.50Fringe $14.78
Rate
CARPENTER
Base $27.00Fringe $7.22
+58 more occupation rates in this WD
Davis-Baconstate match
MD20260126 (Rev 0)
Open WD
Published Jan 02, 2026Maryland • Washington
Rate
BALANCING TECHNICIAN
Base $47.92Fringe $24.44
Rate
BRICKLAYER
Base $33.46Fringe $25.04
Rate
CARPENTER
Base $30.00Fringe $21.25
+54 more occupation rates in this WD
Davis-Baconstate match
MD20260128 (Rev 0)
Open WD
Published Jan 02, 2026Maryland • Worcester
Rate
BALANCING TECHNICIAN
Base $26.25Fringe $8.29
Rate
BRICKLAYER
Base $37.50Fringe $14.78
Rate
CARPENTER
Base $30.54Fringe $18.76
+53 more occupation rates in this WD

Point of Contact

Name
Theresa Thomas
Email
theresa.thomas7@va.gov
Phone
Not available

Agency & Office

Department
VETERANS AFFAIRS, DEPARTMENT OF
Agency
VETERANS AFFAIRS, DEPARTMENT OF
Subagency
245-NETWORK CONTRACT OFFICE 5 (36C245)
Office
Not available
Contracting Office Address
Linthicum, MD
21090 USA

More in NAICS 333914

Description

AMENDMENT TO SOLICITATION - 36C24526Q0377 It is being added to the STATEMENT OF WORK **The contractor must provide a 1 thick steel road plates to be placed under the tank supports. Plates to extend out approximately 2 radially from the support to distribute the load.** B.2 STATEMENT OF WORK LR Boiler Reserve Fuel Tank SCOPE OF WORK: The purpose of this project is to purchase and install a 6,000-gallon reserve fuel tank to support the boiler at the Loch Raven VA property. The fuel tank will supplement the existing reserve fuel tank and be placed on the existing asphalt drive lane adjacent to the emergency generator. The project includes delivery, installation, fuel line connection, and securing the tank area. Delivery and Installation of Fuel Tank: Provide and install a new UL 142 double-wall steel 6,000-gallon, 8 ft diameter skid-mounted aboveground storage tank (AST). The tank will include all required components and fittings such as venting, manway lid, spill bucket, overfill control valve, stick port, visual level gauge, and anti-siphon control. The tank will be white and have all required labels and signage. Fuel Piping Installation: Install 1-inch supply and return piping with all required valves and fittings. Support the piping properly and connect it to the existing piping outside the building at the sump. Fuel Delivery: The owner will provide a fuel delivery to the tank. Installation of Concrete Barriers: Install six (6) traffic barriers to protect the tank. The barriers will be placed on the asphalt adjacent to the tank and spaced out to provide access to the tank. Secured Perimeter Installation: Install a 6 ft construction fence around the tank. One section of the fence will be designed to open for tank access. Integration with Existing Monitoring System: Install a refurbished probe with a diesel and water float kit. Install all wiring and conduit in compliance with the manufacturer s recommendations and the National Electric Code. Install an interstitial sensor in the tank secondary along with all necessary wiring and connections. Program the existing Veeder Root console to monitor the diesel probe and sensor. Program the overfill alarm to activate at 90% capacity, providing overfill protection for the new 6,000-gallon diesel tank. **The contractor must provide a 1 thick steel road plates to be placed under the tank supports. Plates to extend out approximately 2 radially from the support to distribute the load.** DELIVERABLES: 6,000-Gallon Tank Installation: UL 142 double-wall steel tank, including all required fittings and components. Secure fencing and traffic barriers to protect the tank. Fuel Piping: Installed supply and return piping with necessary and compatible valves and fittings. Monitoring System Integration: Refurbished probe with diesel and water float kit. Installed interstitial sensor and all necessary wiring. Programmed Veeder Root console for monitoring and overfill protection. Responsibilities: Contractor: Responsible for the delivery and installation of the fuel tank and associated components. Responsible for installing the piping, barriers, and fencing. Responsible for integrating the tank with the existing Veeder Root monitoring system. The tank will be installed directly on the existing asphalt driveway. All work is to be performed in compliance with relevant regulations and safety standards. EVALUATION FACTORS: Vendor must be registered in SAM.gov; all bid quotes must provide a letter of authorization to distribute supplies on a letterhead from manufacturer; Best Value; Delivery Lead times stated; complete BAA certificate.

Files

Files size/type shown when available.

BidPulsar Analysis

A practical, capture-style breakdown of fit, requirements, risks, and next steps.

Analysis is being generated for this notice. Check back shortly.

FAQ

How do I use the Market Snapshot?

It summarizes awarded-contract behavior for the opportunity’s NAICS and sector, including a recent pricing band (P10–P90), momentum, and composition. Use it as context, not a guarantee.

Is the data live?

The signal updates as new awarded notices enter the system. Always validate the official award and solicitation details on SAM.gov.

What do P10 and P90 mean?

P10 is the 10th percentile award size and P90 is the 90th percentile. Together they describe the typical spread of award values.