Skip to content
Department of Veterans Affairs

6515--ACIST CVi Contrast Dye Injector System

Solicitation: 36C25926Q0221
Notice ID: 45e3ce3236f244879f522c5b0fe36a18
TypeSources SoughtNAICS 339112PSC6515DepartmentDepartment of Veterans AffairsStateCOPostedJan 30, 2026, 12:00 AM UTCDueFeb 06, 2026, 05:00 PM UTCExpired

Sources Sought from VETERANS AFFAIRS, DEPARTMENT OF • VETERANS AFFAIRS, DEPARTMENT OF. Place of performance: CO. Response deadline: Feb 06, 2026. Industry: NAICS 339112 • PSC 6515.

Market snapshot

Awarded-market signal for NAICS 339112 (last 12 months), benchmarked to sector 33.

12-month awarded value
$184,184,070
Sector total $20,341,046,444 • Share 0.9%
Live
Median
$192,500
P10–P90
$32,667$37,205,000
Volatility
Volatile200%
Market composition
NAICS share of sector
A simple concentration signal, not a forecast.
0.9%
share
Momentum (last 3 vs prior 3 buckets)
+143694%($183,928,070)
Deal sizing
$192,500 median
Use as a pricing centerline.
Live signal is computed from awarded notices already observed in the system.
Signals shown are descriptive of observed awards; not a forecast.

Related hubs & trends

Navigate the lattice: hubs for browsing, trends for pricing signals.

We write these bids →
Open on SAM.gov →
Map for CO
Live POP
Place of performance
Department of Veterans Affairs Eastern Colorado VA Health Care System, Rocky Mountain Regional Medical Center 1700 North Wheeling Street • Aurora, Colorado • 80045 United States
State: CO
Contracting office
Greenwood Village, CO • 80111 USA

Point of Contact

Name
Noaa Lanotte
Email
Noaa.Lanotte@va.gov
Phone
303-712-5794

Agency & Office

Department
VETERANS AFFAIRS, DEPARTMENT OF
Agency
VETERANS AFFAIRS, DEPARTMENT OF
Subagency
NETWORK CONTRACT OFFICE 19 (36C259)
Office
Not available
Contracting Office Address
Greenwood Village, CO
80111 USA

More in NAICS 339112

Description

The Department of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for ACIST CVi Contrast Dye Injector (brand name or equal) for the Rocky Mountain Regional VA Medical Center. This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided. Salient Characteristics: -Multi-use syringe usage -Power requirements factory selectable 100 to 120 VAC, 50-60 Hz -10 A maximum or 200 to 240 VAC, 50-60 Hz -Up to a 30% reduction in contrast delivered to patient without compromising image quality -Real-time Dose Tracking -Hand Controller with Variable Rate Technology -Smaller Catheter use option -Twelve design elements that mitigate air injection during angiography -Multi-use syringe usage -Air Column Detect sensor -Manifold capability to prevent reverse flow -Automatic hemodynamic monitoring capability -Contrast flow rates: user-responsive, pre-set Variable and Fixed rates -Fixed saline flow rates -Injection modes: Cardiac & Peripheral Vascular -Pressure Limits minimum 200 to 1200psi -Allow contrast syringe for use in up to 6 patient cases -Single and dual pressure monitoring capability The purchase shall include manufacturer s warranty for the life of the equipment that begins on the date of installation. Warranty shall include the following: Preventive maintenance must be done by OEM certified technicians using OEM certified parts and should at minimum include the following: Annually: -Full system calibration and diagnostics -Software updates and hardware firmware verification -Inspection and replacement of internal filters -Verification of pressure sensor accuracy -Inspection of electrical components and mechanical joints -Safety checks -Grounding integrity -Emergency shutoff verification As Needed: OEM Repair Services Error Code Response and Diagnostics Part Number(s): CLIN Part Number Nomenclature Unit of Measure Quantity 0001 019398 ACIST CVi Contrast Dye Injector System with 7-year Warranty (Brand Name or Equal) EA 1 Responses shall be submitted to Noaa.Lanotte@va.gov by 10:00am MT on February 6, 2026. This notice is intended strictly for market research. The purpose of this Sources Sought Notice is to determine interest and capability of potential qualified sources of supply and determine the socioeconomic size classification of the supplier and manufacturer of the end item. Interested companies shall provide, at a minimum, the following information with their response; Company Name and Address: Point of Contact (POC) Name: Email Address: Phone Number: SAM.gov UEI: On GSA/FSS Schedule or VA Contract? Manufactured in the USA? The anticipated North American Industry Classification System (NAICS) code is 339112- Surgical and Medical Instrument Manufacturing. Mark if your firm is eligible for participation in one of the following small business programs. If so, please indicate the program: [ ] yes [ ] no - Small Business (SB) [ ] yes [ ] no - HUBZone [ ] yes [ ] no - Small Business 8(a) [ ] yes [ ] no - Small Disadvantaged Business (SDB) [ ] yes [ ] no - Women-Owned (WO) Small Business [ ] yes [ ] no - Service Disabled Veteran Owned Small Business (SDVOSB) [ ] yes [ ] no - Veteran Owned Small Business (VOSB) [ ] yes [ ] no - Large Business [ ] yes [ ] no - Other (please specify) Please answer the following questions: [ ] yes [ ] no - Does not exceed 500 employees; (for NAICS 339112), must be verifiable thru the System for Award Management) [ ] yes [ ] no - Is primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied; [ ] yes [ ] no - Takes ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice (identify how this occurs); and [ ] yes [ ] no - Will supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406. Place of Manufacture:____________________________ Note: Do not include Proprietary, classified, confidential, or sensitive information in responses. In addition to providing the information requested above, responding companies are encouraged to include any relevant information (specifications, cut sheets, brochures, capability statement, past experience etc.) to confirm the company s ability to meet the requirements outlined in this request. Responses to this notice are not offers and cannot be accepted by the U.S. Government to form a binding contract or agreement. This notice shall not be construed as a commitment by the Government to issue a solicitation, or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued.

Files

Files size/type shown when available.

BidPulsar Analysis

A practical, capture-style breakdown of fit, requirements, risks, and next steps.

Analysis is being generated for this notice. Check back shortly.

FAQ

How do I use the Market Snapshot?

It summarizes awarded-contract behavior for the opportunity’s NAICS and sector, including a recent pricing band (P10–P90), momentum, and composition. Use it as context, not a guarantee.

Is the data live?

The signal updates as new awarded notices enter the system. Always validate the official award and solicitation details on SAM.gov.

What do P10 and P90 mean?

P10 is the 10th percentile award size and P90 is the 90th percentile. Together they describe the typical spread of award values.