DHS Murray SP-Rental of Portable Chiller Chilled HVAC Operations
Federal opportunity from DEVDISBLTS444 - Developmental Disabilities • DHS - Human Services. Place of performance: IL. Response deadline: Sep 16, 2024.
Market snapshot
Baseline awarded-market signal across all contracting (sample of 400 recent awards; refreshed periodically).
Related hubs & trends
Navigate the lattice: hubs for browsing, trends for pricing signals.
Point of Contact
Agency & Office
Description
DHS Murray SP-Rental of Portable Chiller Chilled HVAC Operations Murray Developmental Center is seeking bids for Portable Chiller Unit, Pump and Generator rental for Emergency Chilled HVAC Operations. Vendor must supply an Chiller capable of producing 110 tons minimum with pump. Please see Scope of Service. Item # 1: ( 981 - 12 ) W.G. Murray Developmental Center is seeking bids for Portable Chiller Unit, Pump and Generator rental for Emergency Chilled HVAC Operations. Vendor must supply an Chiller capable of producing 110 tons minimum with pump. Specs provided: Temperature expected: 72 degree. Flow Rate: 300 gpm at 60 ft. of head. Enter Water Temp (EWT): 55 Degree. Leaving Water Temp: 45-49 Degree. Pressure differential thru system: Delta P: 30psi. Minimum Electrical distance for tie-in: 125 ft. Minimum Piping distance for tie-in: 125 ft. for Supply, 125 ft. for Return. Existing Pipe size: 5in. Can utilize 6in. if possible. If Chiller Unit has 4in. lines then Booster Pump must be utilize with 300/100gpm electrical capacity. Generator must produce minimum of 187kw, Diesel fuel if applicable to support Chiller and Booster Pump if needed. Must provide Diesel GPH for operation of unit. Vendor must supply preventative maintenance. Vendor must insure Chiller and Generator are trailered, Booster Pump is exempted. Vendor must provide staff for mobilize and demobilize. Vendor must provide startup and advise appropriate staff. Vendor must be available for technical issues that may arise 24/7/365. Vendor must report to Facility Chief Engineer for all operations. Vendor must inspect prior to bid. W.G. Murray Developmental Center is seeking bids for Portable Chiller Unit, Pump and Generator rental for Emergency Chilled HVAC Operations. Vendor must supply an Chiller capable of producing 110 tons minimum with pump. Specs provided: Temperature expected: 72 degree. Flow Rate: 300 gpm at 60 ft. of head. Enter Water Temp (EWT): 55 Degree. Leaving Water Temp: 45-49 Degree. Pressure differential thru system: Delta P: 30psi. Minimum Electrical distance for tie-in: 125 ft. Minimum Piping distance for tie-in: 125 ft. for Supply, 125 ft. for Return. Existing Pipe size: 5in. Can utilize 6in. if possible. If Chiller Unit has 4in. lines then Booster Pump must be utilize with 300/100gpm electrical capacity. Generator must produce minimum of 187kw, Diesel fuel if applicable to support Chiller and Booster Pump if needed. Must provide Diesel GPH for operation of unit. Vendor must supply preventative maintenance. Vendor must insure Chiller and Generator are trailered, Booster Pump is exempted. Vendor must provide staff for mobilize and demobilize. Vendor must provide startup and advise appropriate staff. Vendor must be available for technical issues that may arise 24/7/365. Vendor must report to Facility Chief Engineer for all operations. Vendor must inspect prior to bid.
Files
Files size/type shown when available.
BidPulsar Analysis
A practical, capture-style breakdown of fit, requirements, risks, and next steps.
FAQ
How do I use the Market Snapshot?
It summarizes awarded-contract behavior for the opportunity’s NAICS and sector, including a recent pricing band (P10–P90), momentum, and composition. Use it as context, not a guarantee.
Is the data live?
The signal updates as new awarded notices enter the system. Always validate the official award and solicitation details on SAM.gov.
What do P10 and P90 mean?
P10 is the 10th percentile award size and P90 is the 90th percentile. Together they describe the typical spread of award values.