Skip to content
Miami-Dade County

60 YEAR RECERTIFICATION OF MOSQUITO CONTROL ADMIN BLDG NO 5 - STRUCTURAL AND ELECTRICAL REPAIRS

Solicitation: RPQ No 18624-25
Notice ID: ce059a904d375f0673c19515c2c0c941
DepartmentMiami-Dade CountyAgencyStrategic Procurement Department (SPD)StateFLPostedFeb 26, 2026, 12:00 AM UTCDueMar 26, 2026, 06:00 PM UTCCloses in 28 days

Federal opportunity from Strategic Procurement Department (SPD) • Miami-Dade County. Place of performance: FL. Response deadline: Mar 26, 2026.

Market snapshot

Baseline awarded-market signal across all contracting (sample of 400 recent awards; refreshed periodically).

12-month awarded value
$68,699,272,131
Sector total $68,699,272,131 • Share 100.0%
Live
Median
$253,715
P10–P90
$29,763$10,909,709
Volatility
Volatile200%
Market composition
NAICS share of sector
A simple concentration signal, not a forecast.
100.0%
share
Momentum (last 3 vs prior 3 buckets)
+100%($68,699,272,131)
Deal sizing
$253,715 median
Use as a pricing centerline.
Live signal is computed from awarded notices already observed in the system.
Signals shown are descriptive of observed awards; not a forecast.

Related hubs & trends

Navigate the lattice: hubs for browsing, trends for pricing signals.

We write these bids →
Open on official portal →
Map for FL
Live POP
Place of performance
Miami-Dade County, FL
State: FL
Contracting office
Not listed

Point of Contact

Not available

Agency & Office

Department
Miami-Dade County
Agency
Strategic Procurement Department (SPD)
Subagency
Strategic Procurement Department (SPD)
Office
Strategic Procurement Department (SPD)
Contracting Office Address
Not available

Description

Site Hours of Operation: Monday – Friday, 7am-3:30 pm Work Hours: Monday – Saturday, 7am-5 pm • Requests for approval to work outside of regular working hours must be submitted to the Owner at least 48 hours prior to any proposed work. This requirement applies to all weekend work and any extended work hours during weekdays. Project Description: The work consists of furnishing all materials, labor, and equipment to perform the necessary structural and electrical repairs required for the 60 Year Recertification of the Mosquito Control Administration Building (Building No. 5) located at 8901 NW 58th Street, Miami, FL 33178. These repairs are required to comply with the minimum inspection procedural guidelines for Building Recertification, Parking Lot Illumination and Parking Lot Guardrails. The contractor shall be responsible for the following: Structural repairs to include but are not limited to: 1. Repair of cracks on stucco and walls. 2. Repair of concrete spalling on exterior and interior walls. 3. Clean and paint rusted steel beams, purling, joists, columns and connections. 4. Clean and paint the exterior and interior masonry and concrete walls. 5. Replacement of damaged expansion joints. 6. Replacement of sealant around air conditioning ducts. Electrical repairs to include but are not limited to: 1. Install new outdoor light above the main entrance door (on wall). 2. Secure existing low-voltage conductors. 3. Remove existing low-voltage communication cables. 4. Install new communications cables. 5. Verify the existing grounding system. Additional Information • Awarded Contractor shall coordinate with County personnel and with the Engineer to phase the work in a manner to minimize impact to office activities. • Building No. 5 will be unoccupied for a period of ten (10) consecutive days to allow for the completion of steel purlin, beams, and columns cleaning and painting work. Work may begin on a Thursday after regular working hours or on a Friday morning.
Technical Certification: Building Contractor, General Building Contractor

Files

Files size/type shown when available.

BidPulsar Analysis

A practical, capture-style breakdown of fit, requirements, risks, and next steps.

Analysis is being generated for this notice. Check back shortly.

FAQ

How do I use the Market Snapshot?

It summarizes awarded-contract behavior for the opportunity’s NAICS and sector, including a recent pricing band (P10–P90), momentum, and composition. Use it as context, not a guarantee.

Is the data live?

The signal updates as new awarded notices enter the system. Always validate the official award and solicitation details on SAM.gov.

What do P10 and P90 mean?

P10 is the 10th percentile award size and P90 is the 90th percentile. Together they describe the typical spread of award values.