VPRO Max2 Low Temp Sterilizers

Solicitation: 36C25526Q0168
Notice ID: 47f4b906478c432186acf7067ca18496
TypeSolicitationNAICS 334510PSC6515Set-AsideNONEDepartmentDepartment of Veterans AffairsStateMOPostedJan 30, 2026, 12:00 AM UTCDueFeb 10, 2026, 05:00 PM UTCExpired

Solicitation from VETERANS AFFAIRS, DEPARTMENT OF • VETERANS AFFAIRS, DEPARTMENT OF. Place of performance: MO. Response deadline: Feb 10, 2026. Industry: NAICS 334510 • PSC 6515.

Market snapshot

Awarded-market signal for NAICS 334510 (last 12 months), benchmarked to sector 33.

12-month awarded value
$19,321,308
Sector total $20,447,912,679 • Share 0.1%
Live
Median
$40,208
P10–P90
$24,237$91,537
Volatility
Volatile167%
Market composition
NAICS share of sector
A simple concentration signal, not a forecast.
0.1%
share
Momentum (last 3 vs prior 3 buckets)
+100%($19,321,308)
Deal sizing
$40,208 median
Use as a pricing centerline.
Live signal is computed from awarded notices already observed in the system.
Signals shown are descriptive of observed awards; not a forecast.

Related hubs & trends

Navigate the lattice: hubs for browsing, trends for pricing signals.

We write these bids →
Open on SAM.gov →
Map for MO
Live POP
Place of performance
Kansas City, Missouri • 64128 United States
State: MO
Contracting office
Leavenworth, KS • 66048 USA

Point of Contact

Name
Jon Lutmer
Email
Jonathan.lutmer@va.gov
Phone
4104463862

Agency & Office

Department
VETERANS AFFAIRS, DEPARTMENT OF
Agency
VETERANS AFFAIRS, DEPARTMENT OF
Subagency
255-NETWORK CONTRACT OFFICE 15 (36C255)
Office
Not available
Contracting Office Address
Leavenworth, KS
66048 USA

More in NAICS 334510

Description

1. STATEMENT OF WORK
The contractor shall furnish all requisite services, labor, travel, transportation, materials, shipping,
parts, connections, and equipment for the provision and on-site installation of a minimum of three
vaporized hydrogen peroxide Low Temperature Sterilizers. These units are to be located at 4801
Linwood Blvd, Kansas City MO 64128. These low temperature sterilizers are essential for the Sterile
Processing Service (SPS) in reprocessing reusable medical devices (RMDs) employed in invasive
procedures. needed to support Sterile Processing Service (SPS) for reprocessing reuseable medical
devices (RMD) used in invasive procedures. Furthermore, these units are critical for supporting
medical procedures and surgeries and surgeries conducted within the Operating Room, as well as
in various ancillary clinics throughout the KCVA.
The contractor shall additionally furnish training to clinical personnel prior to the utilization of the
equipment. This training is to encompass all tours of duty for the sterile processing department and
necessitate annual retraining on all associated on all associated equipment. Moreover, the
contractor bears the responsibility for the removal and disposal of all debris and packaging
material resulting from the installation of the VPRO MaX2 Low Temp Sterilizers.
2. SPECIFICATIONS
• Three low temperature sterilizers shall have a minimum individual dimensions of Cabinet
(DD): 33 x 40-15/16 x 72” (838 x 1040 x 1829 mm) with Recessed/Cabinet (SD): 33 x
38-5/16 x 72” (838 x 973 x 1829 mm).
o Mounting single door, cabinet
o System installation requires no plumbing, ventilation or air
o supply – only a dedicated electrical connection is needed. A power cord is supplied
for this connection
o The facility space in which the vehicle can occupy is approx. 35’ x 110’.
• Vaporized hydrogen peroxide sterilization processes are particularly suited for sterilizing
heat- sensitive materials because temperatures within the load currently do not exceed
55ºC (131ºF) and sterilization occurs in a low-moisture environment. Heat tolerant devices

and materials can also be indicated for vaporized hydrogen peroxide sterilization processes.
FDA-cleared vaporized hydrogen peroxide sterilizers, either with or without plasma, are
currently available in the United States.
 Per ANSI/AAMI ST58:2013 or subsequent, the sterilizer shall be installed and operated in
an area with a ventilation system capable of at least 10 air exchanges per hour.
 VPRO MaX2 must support utility requirements:
o Current 16 AMP
o Minimum Circuit Breaker 20 AMPS
o Use NEMA L15-20R Plug
o Provide grouped or ganged circuit protection and disconnect for phase 3 power as
required by NEC and local codes.
o Individual power shutoffs near each machine for servicing.
 Shall integrate with the CensiTrac Instrument Tracking System.

Files

Files size/type shown when available.

BidPulsar Analysis

A practical, capture-style breakdown of fit, requirements, risks, and next steps.

Analysis is being generated for this notice. Check back shortly.

FAQ

How do I use the Market Snapshot?

It summarizes awarded-contract behavior for the opportunity’s NAICS and sector, including a recent pricing band (P10–P90), momentum, and composition. Use it as context, not a guarantee.

Is the data live?

The signal updates as new awarded notices enter the system. Always validate the official award and solicitation details on SAM.gov.

What do P10 and P90 mean?

P10 is the 10th percentile award size and P90 is the 90th percentile. Together they describe the typical spread of award values.