IDOC - Sewage Treatment Plant Upgrades
Federal opportunity from CENTRALIACC426 - Centralia Correctional Center • DOC - Corrections. Place of performance: IL. Response deadline: Dec 19, 2025.
Market snapshot
Baseline awarded-market signal across all contracting (sample of 400 recent awards; refreshed periodically).
Related hubs & trends
Navigate the lattice: hubs for browsing, trends for pricing signals.
Point of Contact
Agency & Office
Description
IDOC - Sewage Treatment Plant Upgrades Centralia Correctional Center intends to procure parts and services to upgrade major parts and equipment at the facility's sewage treatment plant. Item # 1: ( 720 - 64 ) 4" Pentair Hydromatic H4HXP (1500DC). 208-volt, 3-phase, 1750 RPM, 9.38# DIA IMP, 540 GPM, 60# TDH, with lower silicon carbide seal and 4" sealing flange 4" Pentair Hydromatic H4HXP (1500DC). 208-volt, 3-phase, 1750 RPM, 9.38# DIA IMP, 540 GPM, 60# TDH, with lower silicon carbide seal and 4" sealing flange Item # 2: ( 720 - 40 ) Square D, 3-pole Starter / Contactor. Part # 8536SE01S, NEMA 3, with heater to match the pumps in Line Item #1, two (2) sets of contacts for this listed starter and one (1) alternating relay and toggle switch for pumps in Line Item #1 Square D, 3-pole Starter / Contactor. Part # 8536SE01S, NEMA 3, with heater to match the pumps in Line Item #1, two (2) sets of contacts for this listed starter and one (1) alternating relay and toggle switch for pumps in Line Item #1 Item # 3: ( 890 - 66 ) Muni Float - Part # 1046374 with 25' Cable Muni Float - Part # 1046374 with 25' Cable Item # 4: ( 720 - 55 ) Tuthill 5006 21L2 Blower Pump, pressure range up to 15 PSIG (1.03 bar g), vacuum range up to 16" Hg (540 mbar g), 570 CFM Tuthill 5006 21L2 Blower Pump, pressure range up to 15 PSIG (1.03 bar g), vacuum range up to 16" Hg (540 mbar g), 570 CFM Item # 5: ( 890 - 28 ) Auma Actuator SQ07.2 quarter turn, electric actuator, AM01.1 Auma Control Unit, 120-volt, 1-phase, 60 Hz, with 6" flange to mount direct. Auma Actuator SQ07.2 quarter turn, electric actuator, AM01.1 Auma Control Unit, 120-volt, 1-phase, 60 Hz, with 6" flange to mount direct.
Files
Files size/type shown when available.
BidPulsar Analysis
A practical, capture-style breakdown of fit, requirements, risks, and next steps.
FAQ
How do I use the Market Snapshot?
It summarizes awarded-contract behavior for the opportunity’s NAICS and sector, including a recent pricing band (P10–P90), momentum, and composition. Use it as context, not a guarantee.
Is the data live?
The signal updates as new awarded notices enter the system. Always validate the official award and solicitation details on SAM.gov.
What do P10 and P90 mean?
P10 is the 10th percentile award size and P90 is the 90th percentile. Together they describe the typical spread of award values.