Skip to content
Department of Veterans Affairs

6515--RFI EQUIPMENT - Brand Name Only INFUSION DEVICE ANALYZER

Solicitation: 36C24226Q0535
Notice ID: bea0c0f27e244a72a653ca0ed248539d
TypeSources SoughtNAICS 334510PSC6515DepartmentDepartment of Veterans AffairsStateNYPostedApr 15, 2026, 12:00 AM UTCDueApr 27, 2026, 08:00 PM UTCExpiredBid range$625,611 - $741,464
Contract snapshot

Sources Sought from VETERANS AFFAIRS, DEPARTMENT OF • VETERANS AFFAIRS, DEPARTMENT OF. Place of performance: NY. Response deadline: Apr 27, 2026. Industry: NAICS 334510 • PSC 6515.

Source
Open on SAM.gov →
Solicitation
36C24226Q0535
Performance
Hudson Valley VA Medical Center Castle Point Campus, 41 Castle Point Rd • Wappingers Falls, New York • 12590 United States
Response
Apr 27, 2026, 08:00 PM UTC
Open on SAM.gov →
Map for NY
Live POP
Place of performance
Hudson Valley VA Medical Center Castle Point Campus, 41 Castle Point Rd • Wappingers Falls, New York • 12590 United States
State: NY
Contracting office
Albany, NY • 12208 USA

Point of Contact

Name
Sanchez Reid
Email
Sanchez.Reid@va.gov
Phone
Telephone inquiries are not allowed.

Agency & Office

Department
VETERANS AFFAIRS, DEPARTMENT OF
Agency
VETERANS AFFAIRS, DEPARTMENT OF
Subagency
242-NETWORK CONTRACT OFFICE 02 (36C242)
Office
Not available
Contracting Office Address
Albany, NY
12208 USA

Applicable wage determinations

Best public WD match for the notice location and scope.

Directory →
Best fitDavis-Baconstate match
NY20260045 (Rev 2)
Published May 18, 2026New York • Tioga
80 occupation rates available in the full WD.
View more WD detail
3 more WD matches and 78 more rate previews.
Davis-BaconBest fitstate match
NY20260045 (Rev 2)
Open WD
Published May 18, 2026New York • Tioga
Rate
WORK: DUTIES LIMITED TO PREPARATION, WETTING, STRIPPING, REMOVAL, SCRAPPING, VACUUMING, BAGGING, AND DISPOSING OF ALL INSULATION MATERIALS, WHETHER THEY CONTAIN ASBESTOS OR NOT FROM MECHANICAL SYSTEM)
Base $38.50Fringe $25.04
Rate
COATINGS AND FINISHINGS TO ALL TYPES OF MECHANICAL SYSTEMS. ALSO THE APPLICATION OF FIRESTOPPING MATERIAL TO OPENINGS AND PENETRATIONS IN WALLS, FLOORS, CEILINGS, CURTAIN WALLS AND ALL LEAD ABATEMENT.)
Base $43.25Fringe $27.29
Rate
BOILERMAKER
Base $43.34Fringe $27.66
+77 more occupation rates in this WD
Davis-Baconstate match
NY20260079 (Rev 1)
Open WD
Published May 18, 2026New York • Clinton, Franklin, Fulton +4
Rate
ELECTRICIAN
Base $43.50Fringe $28.38
Rate
SHEET METAL WORKER (HVAC DUCT INSTALLATION ONLY)
Base $17.41Fringe $2.46
Rate
ROOFER
Base $16.47Fringe $0.36
+8 more occupation rates in this WD
Davis-Baconstate match
NY20260113 (Rev 2)
Open WD
Published May 18, 2026New York • Otsego
Rate
ASBESTOS WORKER/HEAT & FROST INSULATOR (MECHANICAL (DUCT, PIPE & MECHANICAL SYSTEM INSULATION))
Base $43.25Fringe $27.29
Rate
BRICKLAYER
Base $62.54Fringe $29.40
Rate
CEMENT MASON/CONCRETE FINISHER
Base $34.32Fringe $20.52
+23 more occupation rates in this WD
Davis-Baconstate match
NY20260009 (Rev 2)
Open WD
Published May 18, 2026New York • Jefferson, Lewis, St Lawrence
Rate
BOILERMAKER
Base $35.23Fringe $26.61
Rate
THANKSGIVING DAY, CHRISTMAS DAY. FOOTNOTE A. PAID HOLIDAYS: MEMORIAL DAY, JULY THE 4TH, LABOR DAY, AND THANKSGIVING DAY (PROVIDED THE EMPLOYEE IS EMPLOYED ONE DAY BEFORE AND ONE DAY AFTER THE HOLIDAY)
Base $37.23Fringe $19.51
Rate
CARPENTERS: (HEAVY & HIGHWAY CONSTRUCTION) A. PAID HOLIDAYS: NEW YEAR'S DAY, MEMORIAL DAY, INDEPENDENCE DAY, LABOR DAY, THANKSGIVING DAY, CHRISTMAS DAY
Base $39.52Fringe $27.16
+57 more occupation rates in this WD

More in NAICS 334510

Description

THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 12. DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 12, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT DESCRIPTION This is NOT a solicitation announcement. This is a sources sought/RFI only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 334510- Electromedical and Electrotherapeutic Apparatus Manufacturing (size standard of 1,250 Employees). Responses to this sources sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought, a solicitation announcement may be published. Responses to this source sought synopsis are not considered adequate responses for a solicitation announcement. The Department of Veterans Affairs (VA), VISN 02 Network Contracting Office, is seeking sources that can provide the brand name Infusion Device Analyzer that at a minimum meet the following salient characteristics with a brand name product for the Hudson Valley Healthcare System: To Be Delivered to: VA Hudson Valley Medical Center Castle Point Campus 41 Castle Point Road Wappingers Falls, NY 12590 The VA has a preference for domestic (manufactured in the United States) content where available. Specifications: Castle Point VA Medical Center Wappinger Falls, New York Statement of Work (SOW) Four Channel Infusion Device Analyzers Background: The Castle Point VA Medical Center in Wappingers Falls, New York, requires an Infusion Device Analyzer to perform essential preventive maintenance and performance verification on infusion pumps used throughout the facility. This equipment is critical for ensuring compliance with IEC60601-2-24 standards and maintaining patient safety. The infusion device analyzer will allow biomedical engineers to test multiple infusion devices simultaneously, automate workflows, and improve efficiency in documenting results. This acquisition supports regulatory compliance and reduces downtime for critical infusion equipment. Scope of Work: Gas Flow Analyzer The contractor shall provide (2) four channel Infusion Device Analyzers with the following specifications: No optional items are needed with these analyzers. Required Features Workflow Automation: Integrated OneQA software for automated testing and documentation. Multi-Channel Testing: Ability to test up to four infusion pumps simultaneously. Accuracy & Resolution: Flow range: 0 3000 mL/h (steady), 0 1500 mL/h (peristaltic). Flow accuracy: ± (1% + 0.005 mL/h) at 10,000 measurements; ability to upload pictures and instructions. Dimensions & Weight: Approx. 95 mm × 210 mm × 260 mm; weight ~3.8 kg. Power: 19 V DC, 3 A. Safety Requirements Comply with IEC and EMC standards; no additional VA security accreditation required VA 6500.6 The C&A requirements do not apply, and a Security Accreditation Package is not required: Period of Performance Contractor shall deliver item within a week of award date. Place of Delivery Castle Point Campus 41 Castle Point Rd, Wappingers Falls, NY 12590 Inspection The VA COR POC will inspect item upon delivery. VA Privacy Training for Personnel without Access to VA Computer Systems or Direct Access to or the Use of VA Sensitive Information The Department of Veterans Affairs, VA must comply with all applicable privacy and confidentiality statutes and regulations. One of the requirements in VA is to have all personnel trained annually on privacy requirements. Privacy represents what must be protected by VA in the collection, use, and disclosure of personal information whether the medium is electronic, paper or verbal. This document satisfies the basic privacy training requirement for a contractor, volunteer, or other personnel only if the individual does not use VA sensitive information or protected health information (PHI) in any form such as electronic or paper or have access to any VA computer system such as VA Time and Attendance System (VATAS), Computerized Patient Record System (CPRS), Joint Legacy Viewer (JLV), Veterans Health Information Exchange (VHIE), Compensation and Pension Record Interchange (CAPRI). You will find this training outlines your role and responsibility for protecting VA sensitive information (medical, financial, or educational) that you may incidentally or accidentally see or overhear. If you have direct access to VA sensitive information or access to a VA computer system where there is protected health information such as VATAS, CPRS, JLV, VHIE or CAPRI you must take Privacy and HIPAA Focused Training (TMS 10203). VA Privacy and Information Security Awareness and Rules of Behavior (TMS 10176) is always required to use or gain access to a VA computer system or VA sensitive information, whether or not protected health information is included. Both trainings are located within the VA Talent Management System (TMS): https://www.tms.va.gov What is VA Sensitive Information/Data? All Department information and/or data on any storage media or in any form or format, which requires protection due to the risk of harm that could result from inadvertent or deliberate disclosure, alteration, or destruction of the information. The term includes not only information that identifies an individual but also other information whose improper use or disclosure could adversely affect the ability of an agency to accomplish its mission, proprietary information, and records about individuals requiring protection under applicable confidentiality provisions. What is Protected Health Information? The HIPAA Privacy Rule defines protected health information as Individually Identifiable Health Information transmitted or maintained in any form or medium by a covered entity, such as VHA. What is an Incidental Disclosure? An incidental disclosure is one where an individual s information may be disclosed incidentally even though appropriate safeguards are in place. Due to the nature of VA communications and practices, as well as the various environments in which Veterans receive healthcare or other services from VA, the potential exists for a Veteran s protected health information or VA sensitive information to be disclosed incidentally. For example: You overhear a healthcare provider s conversation with another provider or patient even when the conversation is taking place appropriately. You may see limited Veteran information on sign-in sheets or white boards within a treating area of the facility. You may hear a Veteran s name being called out for an appointment or when the Veteran is being transported/escorted to and from an appointment. Safeguards You Must Follow to Secure VA Sensitive Information: Secure any VA sensitive information found in unsecured public areas (parking lot, trash can, or vacated area) until information can be given to your supervisor or Privacy Officer. You must report such incidents to your Privacy Officer timely. Don t take VA sensitive information off facilities grounds without VA permission unless the VA information is general public information, i.e., brochures/pamphlets. Don t take pictures using a personal camera without the permission from the Medical Center Director. Any protected health information overheard or seen in VA should not be discussed or shared with anyone who does not have a need to know the information in the performance of their official job duties, this includes spouses, employers or colleagues. Do not share VA access cards, keys, or codes to enter the facility. Immediately report lost or stolen Personal Identity Verification (PIV) or Veteran Health Identification Cards (VHIC), VA keys or keypad lock codes to your supervisor or VA police. Do not use a VA computer using another VA employee s access and password. Do not ask another VA employee to access your own protected health information. You must request this information in writing from the Release of Information section at your facility What are the Six Privacy Laws and Statutes Governing VA? Freedom of Information Act (FOIA) compels disclosure of reasonably described VA records or a reasonably segregated portion of the records to any person upon written request unless one or more of the nine exemptions apply. Privacy Act of 1974 provides for the confidentiality of personal information about a living individual who is a United States citizen, or an alien lawfully admitted to U.S. and whose information is retrieved by the individual s name or other unique identifier, e.g. Social Security Number. Health Insurance Portability and Accountability Act (HIPAA) provides for the improvement of the efficiency and effectiveness of health care systems by encouraging the development of health information systems through the establishment of standards and requirements for the electronic transmission, privacy, and security of certain health information. 38 U.S.C. 5701 provides for the confidentiality of all VA patient and claimant information, with special protection for their names and home addresses. 38 U.S.C. 7332 provides for the confidentiality of drug abuse, alcoholism and alcohol abuse, infection with the human immunodeficiency virus (HIV) and sickle cell anemia medical records and health information. 38 U.S.C. 5705 provides for the confidentiality of designated medical-quality assurance documents. What are the Privacy Rules Concerning Use and Disclosure? You are not authorized to use or disclose protected health information. In general, VHA personnel may only use information for purposes of treatment, payment or healthcare operations when they have a need-to-know in the course of their official job duties. VHA may only disclose protected health information upon written requests by the individual who is the subject of the information or as the brand name authorized by law. How is Privacy Enforced? There are both civil and criminal penalties, including monetary penalties that may be imposed if a privacy violation has taken place. Any willful negligent or intentional violation of an individual s privacy by VA personnel, contract staff, volunteers, or others may result in such corrective action as deemed appropriate by VA including the potential loss of employment, contract, or volunteer status. Know your VA/VHA Privacy Officer and Information Systems Security Officer. These are the individuals to whom you can report any potential violation of protected health information or VA sensitive information, or any other concerns regarding privacy of VA sensitive information. YOU ARE RESPONSIBLE FOR PROTECTING THE CONFIDENTIAL INFORMATION OF OUR VETERANS Employee (Print Name) Date Employee Signature Print Name of Contract Agency, if contractor Print Name of VHA Department/Supervisor/Contracting Officer PROVIDE A COPY OF THIS FORM TO YOUR SUPERVISOR/CONTRACTING OFFICER FOR DATA ENTRY INTO TALENT MANAGEMENT SYSTEM Item Number Description Quantity 5608365 IDA-6 4-CH, FOUR-CHANNEL INFUSION DEVICE ANALYZER 2 The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. If you are interested and are capable of providing the sought out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: Please indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.)? (2) Is your company considered small under the NAICS code identified under this RFI? (3) Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above? (4) If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available). (5) If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? (6) If you intend to sub contract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to sub contracted work and completion of job. (7) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract number. (8) If you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract? (9) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate any type of award. (10) Please submit your capabilities in regard to the salient characteristics being provided and any information pertaining to equal to items to establish capabilities for planning purposes? (11) Will the items you will be providing manufactured domestically in the United States or are they foreign manufactured items? (12) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A. (13) Please provide your Sam.gov Unique Entity ID number. Responses to this notice shall be submitted via email to Sanchez.Reid@va.gov. Telephone responses shall not be accepted. Responses must be received no later than April 27,2026 at 4:00PM EST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this sources sought. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.

Advisory bid range

Pricing and bid posture

high confidence
$625,611 - $741,464

Contractor-side estimate from visible notice metadata, NAICS/PSC, contract type, schedule hints, and BidPulsar workpaper assumptions. Not an IGCE, incumbent price, award value, or government budget.

Calibrate full bid price →
Floor
$625,611
Target
$662,022
Premium
$741,464
Labor
$329,680
Direct
$32,000
Burden
$221,360
Fee + reserve
$78,022
Target $662,022Hybrid workpaper with explicit assumptions4 modeled rows

This advisory bid range is visible page text for contractors and search engines: it summarizes the modeled floor, target, and premium bid posture for this solicitation.

Market snapshot

Awarded-market signal for NAICS 334510 (last 12 months), benchmarked to sector 33.

12-month awarded value
$92,635,630
Sector total $53,340,602,409 • Share 0.2%
Live
Median
$25,075
P10–P90
$25,075$25,075
Volatility
Stable0%
Market composition
NAICS share of sector
A simple concentration signal, not a forecast.
0.2%
share
Momentum (last 3 vs prior 3 buckets)
-46%(-$27,861,385)
Deal sizing
$25,075 median
Use as a pricing centerline.
Live signal is computed from awarded notices already observed in the system.
Signals shown are descriptive of observed awards; not a forecast.

Files

Files size/type shown when available.

BidPulsar Analysis

A practical, capture-style breakdown of fit, requirements, risks, and next steps.

Analysis is being generated for this notice. Check back shortly.
Federal Bid Partners

Service match

Optional support routes matched to this notice after the core solicitation details.

Notice 36C24226Q0535
Need help writing this bid?
Route this notice into proposal, compliance, and submission support without burying the solicitation record.
Open proposal plans
Other matched support routes

Related hubs & trends

Navigate the lattice: hubs for browsing, trends for pricing signals.